1. The FZ - BW series reverse osmosis membrane element is a polyamide composite membrane developed by Shanghai Feizuo Company for desalination of brackish water. It has the characteristics of low pressure operation, high water production and good desalination performance. It is suitable for desalination treatment of surface water, groundwater, tap water and other water sources with salt content less than 5000ppm. Among them, the 8-inch desalination membrane is mainly used in large and medium-sized chemical, pharmaceutical, food, power plants, and electronic plants. Process pure water, boilers Make-up water, etc., can also be used for desalination and purification of municipal water.


Model

Active Are

a ft2(m2)

Feed Spacer 

Thickness(mil)

Permeate Flow 

Rate GPD(m3/d)

Stabilized Salt 

Rejection (%)

Minimum Salt 

Rejection (%)

FZ-BW-8040-400 400 (37.2) 32 10500 (39.7) 99.50 99.30
FZ-BW-8040-420 420 (39) 30 11000 (41.6) 99.50 99.30
FZ-BW-8040-440 440 (41.0) 28 11500 (43.5) 99.50 99.30
FZ-BW-4040 85 (7.9) 32 2400 (9.1) 99.50 99.30
FZ-BW-4040P 93 (8.6) 28 2500 (9.5) 99.50 99.30
FZ-BW-4040M 103 (9.6) 28 2600 (9.8) 99.50 99.30


2. Element Dimension : 


Model Length Diameter Permeate Tube inner Diameter Permeate Tube
Extension Length
inch mm inch mm inch mm inch mm
8040 40 1016 7.9 201 1.12 28.5 / /
4040 40 1016 3.9 99 0.75 19.1 1.04 26.5


3. Test condition :


Test Pressure 225psi ( 1.55Mpa )
Test Temperature 25
Test Liquid concentration ( NaCI ) 2000ppm
Testing Liquid PH data 7.5
Recovery rate of single RO membrane element 15%


4. Operative limits


Highest temperature of Inlet water 113  F ( 45 )
Highest Operating Pressure 600psi ( 5.14Mpa )
Maximum Pressure Drop
of Single RO Membrane element 
15psi (0.1M Pa)
Inlet water PH data range of continuous operating 3 - 10.
Inlet water PH data range of chemical cleaning 2 - 12.
Highest Inlet water flow 16gpm ( 3.6m/h )
Biggest Inlet water SDI 15 5
Inlet water free chlorine concentration < 0.1ppm

Product Categories : RO Membrane

Email to this supplier
  • *Subject:
  • *To:
    Ms. Fiona.Xi
  • *Email:
  • *Message:
    Your message must be between 20-8000 characters
Home > Products > RO Membrane > Brackish Water RO Membrane
Send Inquiry
*
*

Related Products List

Home

Product

Phone

About Us

Inquiry

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send